THUM Temperature Humidity Device

Setup THUM device to automatically record temperature and humidity

Ape software is compatible with the Temperature and Humidity USB Monitor (THUM) sold by Practical Design Group.  With a THUM device plugged in and setup on your computer, Ape can automatically retrieve temperature and humidity data for calibration events.

THUM Device

Setup

Follow these instructions to integrate the THUM with Ape:

  1. Setup THUM:  Follow the setup instructions that arrive with THUM.
  2. Move THUM Database:  The default location of the THUM database (thum.mdb) is in the Program Files folders.  This will only work if the signed in user has read/write access to the Program Files folders.  Therefore, always move the database out of the Program Files folder to a location where everyone has read/write access, like the CC Settings folder.
    1. Move the THUM database by opening the THUM application and selecting 'Show Options' from the Options dropdown menu.
    2. Update the ‘Database location’ field to reflect the new location, like the CC Settings folder.
  3. Tell Ape Where THUM Is:  Open the Folders tab of the Options dialog in the Ape database and click the Edit link in the ‘Location of THUM . . .’ field.  Navigate to the same location as above.
  4. Test Setup:  Test the setup be creating a new Calibration Event record (Calibrations tab of Equipment Edit dialog) and confirming that the Temp and Humidity fields are automatically populated.
THUM Options

Troubleshooting

  • Insufficient Permissions:  Attempt to start the THUM Monitor software and it reports that the current user has insufficient permissions to make changes.  Resolve this by running the THUM monitor as an Administrator.  Do this by right-clicking on the THUM icon and selecting "Run as Administrator".
  • THUM Service Will Not Start:  If the THUM service cannot be started from the THUM Monitor, one or more of the following steps should fix the problem.  For a complete reset, follow each step:
    1. Close THUM Monitor:  Resets the software.
    2. Delete THUM Database:  Delete the "thum.mdb" file that the THUM Monitor is pointed to.  Ensure this is not the database in the Program Files folders, which should not be used for live data.  Deleting the database resets the database file to ensure no corruption and that (thum.mdb) is in the proper version format for the THUM service.  Therefore, when opening the "thum.mdb" file with MS Access, do not allow Access to convert the "thum.mdb" file to a newer version of MS Access.
    3. Reset THUM Device:  Ensure the electronic THUM device itself is reset by unplugging it from the computer for at least 5 seconds and plugging it back in.
    4. Restart THUM Monitor:  Remember to start the THUM Monitor with Administrator Privileges, if necessary.
  • Still Need Help?:  Contact us if the above steps did not work and we will get you up and running.

Last updated:  27 Feb 2017

Compatibility:  Calibration Control 7.3 and higher